B.E.S.T. PILES DESCRIPTION
Piles were codified according its construction methodology.
A-type: bored piles with retrievable casing
B-type: Continuous Flight Auger (CFA)
C-type: Full Displacement Pile (FPD)
D type: Self boring piles
E-type: Vibro-driven micropiles
F-type: Drilled with bentonite
G-type: Helical pile.
DC-type: Drilled cased
Type of load tests, different types of tubes and wires were placed for Integrity test according to the following table:
To view the test layout in detail:
Download
(pdf)
Updated 04/07/2019